Error code
Description
Action
405-904-
xxx
Failed the Broadcom Ethernet tests due to a
failure in interrupts
1. Make sure that the component firmware level is
up-to-date, and upgrade if necessary. The
installed firmware level can be found in the DSA
log within the Firmware/VPD section for this
component. The latest level firmware for this
component can be found at http://www.ibm.com/
support/ fixcentral/systemx/groupView? query.
productGroup=ibm%2FBladeCenter.
2. Run the test again.
3. If the failure remains, refer to Chapter 4
“Removing and replacing blade server
components” on page 65 to replace the failed
component.
405-905-
xxx
Failed the Broadcom Ethernet tests due to a
failure in loopback test at MAC layer.
1. Make sure that the component firmware level is
up-to-date, and upgrade if necessary. The
installed firmware level can be found in the DSA
log within the Firmware/VPD section for this
component. The latest level firmware for this
component can be found at http://www.ibm.com/
support/ fixcentral/systemx/groupView? query.
productGroup=ibm%2FBladeCenter.
2. Run the test again. See “Diagnostic tools
3. If the failure remains, refer to Chapter 4
“Removing and replacing blade server
components” on page 65 to replace the failed
component.
252
BladeCenter HX5 Blade ServerProblem Determination and Service Guide
Содержание BladeCenter HX5 1909
Страница 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 16: ......
Страница 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Страница 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 311: ......
Страница 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Страница 313: ... 1P46W8208 ...