To remove a DIMM, complete the following steps:
Step 1. Before you begin, read “Safety” on page v and “Installation guidelines” on page 65.
Step 2. Carefully lay the expansion blade on a flat, static-protective surface.
Step 3. Open the expansion blade cover (see “Removing the blade server cover” on page 71 for
instructions).
Step 4. If the IBM MAX5 expansion blade is installed on an BladeCenter HX5 blade server that is installed in
a BladeCenter chassis:
a. Remove the blade server from the chassis (see “Removing the blade server from the
BladeCenter chassis” on page 66 for instructions).
b. Remove the IBM MAX5 expansion blade (see “Removing an IBM MAX5 expansion blade” on
page 87 for instructions).
Step 5. Locate the DIMM connectors (see “Blade server connectors - IBM MAX5” on page 14). Determine
which DIMM you want to remove from the expansion blade.
Attention:
To avoid breaking the retaining clips or damaging the DIMM connectors, handle the
clips gently.
Step 6. Make sure that both retaining clips on DIMM connector from which you will be removing the DIMM
are in the open position.
Step 7. Using your fingers, pull the DIMM out of the connector.
Step 8. If you are instructed to return the DIMM, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
Installing a DIMM - IBM MAX5
The expansion blade has a total of 24 dual inline memory module (DIMM) connectors. The expansion blade
supports 2 GB (Type 7873 models), 4 GB, 8 GB, 16 GB (Type 7873 models), and 32 GB (Type 7873 models)
memory DIMMs. Typically, you will install all memory supported by the BladeCenter HX5 blade server before
installing memory in the IBM MAX5 expansion blade.
There are two versions of the IBM MAX5 expansion blade, referred to as the IBM MAX5 version 1 and IBM
MAX5 version 2 in this document. IBM MAX5 version 2 has a "MAX5" identifying label on the bottom of the
front bezel. The functionality of the two IBM MAX5 expansion blades are equivalent except the type of
DIMMs supported. The type of DIMMs supported will differ, depending on the version of IBM MAX5
expansion blade installed.
108
BladeCenter HX5 Blade ServerProblem Determination and Service Guide
Содержание BladeCenter HX5 1909
Страница 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 16: ......
Страница 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Страница 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 311: ......
Страница 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Страница 313: ... 1P46W8208 ...