Group 8
Job Editor
Page 167
JET3 Series
Release 2.02
7.4.4 Special functions and tools
Under the tab
<Special Functions/Tools>
the following functions are available:
Pressureless
Calc last PG Drops
Constant Bleed
Mix only Ink
Deplete Ink
Mix only Solvent
Deplete Solvent
Fill up Routine
Calc Delay Time
Ignore error messages and warnings
7.4.4.1 Constant bleed
ATTENTION
The function constant bleeding is only activated or functional under the
following device conditions:
Ink suction is turned on
Nozzle is closed
Head cover is removed
By pressing the button
<Constant Bleed> (1)
the constant bleeding is started. During the
process the message
„Constant Bleed“
(2)
is displayed. The bleeding can be canceled
any time by pressing on the button
<Stop>
(3)
. During this process the visco pump is
activated for 3 sec. every minute to ensure a purging of the pump.
With the button
<Add Solv> (4)
you can add only solvent. This function provides specially
filling operations to bleed e.g. the solvent tube or to set the viscosity of the ink faster to a
lower value.
ATTENTION
By adding solvent the ink can be diluted too strong. Therefore this function
should only be carried out by qualified personnel.
Содержание JET3
Страница 1: ...Operating Manual V2 02 Please keep for future reference ...
Страница 2: ......
Страница 21: ...Group 2 Safety Page 19 JET3 Series Release 2 02 2 4 Safety sticker Figure 1 Safety sticker Safety sticker ...
Страница 380: ...Page 378 Appendix Connection Examples for the Interfaces Group 12 Release 2 02 JET3 Series Interface X3 Outputs ...
Страница 390: ...Page 388 Appendix List of illustrations Group 12 Release 2 02 JET3 Series 12 4 2 Print head SK 6 ...
Страница 391: ...Group 12 Appendix List of illustrations Page 389 JET3 Series Release 2 02 12 4 3 Print head SK 4 Option ...
Страница 392: ...Page 390 Appendix List of illustrations Group 12 Release 2 02 JET3 Series 12 4 4 Cabinet JET printer ...