![Honeywell Galaxy Flex 100 V3 Скачать руководство пользователя страница 64](http://html.mh-extra.com/html/honeywell/galaxy-flex-100-v3/galaxy-flex-100-v3_installer-manual_153326064.webp)
Codes [42, Quick Menu 7]
Galaxy Flex Installer Manual
64
To assign a level to a user:
1.
Type the level to be assigned.
2.
Press
ent
.
EN50131-1
Level
Level
Access Availability
1
0
†
Guard
Entered into event memory – no other option
2
1
†
Guard
Can only set the system and change own PIN
2
2
†
Caretaker
Can only set and unset the system and change own PIN
2
3
Users
Menu options 11 to 19
2
4
Users
Menu options 11 to 25
2
5
Users
Menu options 11 to 32
2
6
‡
Manager
Menu options 11 to 48
3
7
‡
Engineer
Menu options 11 to 72
3
8
‡
Remote
Menu options 11 to 72
† No access to menu functions
‡ The manager, engineer and remote codes (the last three codes on the system) have fixed
types which cannot be reprogrammed.
Note:
All levels except Guard 0 can change their own PIN.
Duress Code
Entry of a Duress Code sends a signal to the monitoring station to indicate a user has been
forced to operate the system under duress. Any user on the system can be designated as a
Duress Code. There is no limit to the number of users that can be assigned as Duress Codes.
To assign a Duress Code:
In the
Modify Level
option, press
#
. The current user code is assigned as a Duress
Code.
To assign a User Code as duress:
Enable the
Duress User [51.77]
option.
Quick Menu
All user codes default to the quick menu. This menu is made up of a selection of ten options
(0 – 9) from the full menu. Access to the quick menu is controlled by the user type. Any
user can be upgraded from the quick menu to the full menu by assigning a
to the user
while the Modify Type option is accessed. Therefore a user with type 5 would have access
to the full menu from options 11 – 32. It is not possible to access both menus at the same
time.
To reprogram the options contained in the quick menu refer to
Quick Menu [59]
.
Note:
The master manager code defaults to the full menu.