![Honeywell Galaxy Flex 100 V3 Скачать руководство пользователя страница 202](http://html.mh-extra.com/html/honeywell/galaxy-flex-100-v3/galaxy-flex-100-v3_installer-manual_153326202.webp)
Appendix B: SIA & contact ID event codes
Galaxy Flex Installer Manual
202
Ev
SIA Event
Log
Log Event
Ev Type Trigger
Contact
Description
Event
Description
ID Event
CL
Closing Report
FULL SET
Full set
USER
10.SETTING
401
FULL SET
Set by keypad
EVENT
10.SETTING
401
KSW SET
Keyswitch set
ZONE
10.SETTING
409
CP
Auto. Closing
REARM
Re-arm after alarm
EVENT
10.SETTING
463
CR
Recent Close
RECEN.SET
Previous alarm was within
EVENT
2.INTRUDER
459
5 mins of set
CT
Late to Open
TIMEOUT
Entry timeout
EVENT
10.SETTING
None
D - Access
DD
Access Denied
Invalid Card
MAX tag unknown
MOD
17.MAXTAG
421
DF
Door Forced
MAX ALARM
Door contact broken
MOD
4.SECURITY
423
17.MAXTAG
DCM EVENT
Door contact broken
MOD
4.SECURITY
423
DG
Access Granted
LEGAL CD
Legal code entered
USER
16.LOG
462
LEGAL CD
ATM code entered
USER
16.LOG
462
Valid
MAX tag accepted
USER
17.MAXTAG
422
DK
Access Lockout
ILL-CODE
Illegal code entry
USER
16.LOG
421
REJECT CARD
Illegal MAX tag
USER
17.MAXTAG
421
FOB REJECT
Illegal Fob
ZONE
10.SETTING
421
DK
Access Lockout
DCM EVENT
Invalid Card Reader Lockout
USER
16.LOG
421
10.SETTING
17.MAXTAG
DT
Door propped
DOOR PROP
MAX - Door left open
MOD
4.SECURITY
426
E - System Trouble
ER
Mod Removed
REMOVED
Module Removed
MOD
TAMPER
532
ET
RF NVM Fail
RF MEM!
RF NVM RAM Fail
MOD
TAMPER
333
F - Fire
FA
Fire Alarm
FIRE+
Fire zone alarm
ZONE
6.FIRE
110
FB
Fire Bypass
OMITTED
Fire zone omitted
ZONE
8.OMIT
573
F
Force omit after rearm
ZONE
8.OMIT
573
FJ
Fire Troub rest
LOW RES-
Restor zone resistance
ZONE
15.TROUBL
380
HIGH RES-
Restor zone resistance
ZONE
15.TROUBL
380
FR
Fire Restoral
FIRE-
Fire zone restored
ZONE
6.FIRE
110
18.ZN RESTO
FT
Fire Trouble
LOW RES+
Low resistance on zone
ZONE
15.TROUBL
380
HIGH RES+
High resistance on zone
ZONE
15.TROUBL
380
FU
Fire Unbypass
FORCE OMT-
Unomitted after rearm
ZONE
8.OMIT
573
FV
Fire Confirm
FIRE CONF
2 independent fire alarms
EVENT
6.FIRE
139
FX
Fire Test
FIRE
Fire zone tested
ZONE
NOT SENT
None
SOAK TEST
Soak test fire zone act
ZONE
NOT SENT
None
G - Gas (Custom SIA - See Note 2)
GA
Alarm
Note 1
zone in alarm
ZONE
5.CUS ZON
Note 1
GB
Bypass
OMITTED
zone omitted
ZONE
8.OMIT
Note 1
F
Force omit after rearm
ZONE
8.OMIT
Note 1
GJ
Trouble Rest
LOW RES-
Restor zone resistance
ZONE
15.TROUBL
Note 1
HIGH RES-
Restor zone resistance
ZONE
15.TROUBL
Note 1
GR
Alarm Restore
Note 1
zone restored
ZONE
5.CUS ZON
Note 1
18.ZN RESTO
GT
Trouble
LOW RES+
Low resistance on zone
ZONE
15.TROUBL
Note 1
HIGH RES+
High resistance on zone
ZONE
15.TROUBL
Note 1
GU
Unbypass
FORCE OMT-
Unomitted after rearm
ZONE
8.OMIT
Note 1