![Honeywell Galaxy Flex 100 V3 Скачать руководство пользователя страница 180](http://html.mh-extra.com/html/honeywell/galaxy-flex-100-v3/galaxy-flex-100-v3_installer-manual_153326180.webp)
Pre-checks [66]
Galaxy Flex Installer Manual
180
Pre-checks [66]
This option provides added system security by alerting the user to zones that may not be
operating correctly.
Note:
Pre-check does not operate when the system is in the engineer mode.
Testing Zones
The entry/exit horns beep once when each zone is tested. As each zone is successfully
tested, the keypad indicates the number that remains to be tested. When the last zone is
successfully tested the entry/exit horn sounds twice and the keypad displays
0 CHECK
ZONES
; press
ent
to resume the system routine.
1=Mode
The Mode determines the pre-check level that the selected zones are subjected to before the
system can set. The Mode is selected from one of the following:
Disabled
(default): the pre-check option is disabled; even if zones are selected, they are not
checked.
Warning:
when the setting routine is started the user is informed of the number of selected
pre-check zones that have not been activated since the system was unset. Press
A
or
B
to
view the zones. Press
ent
to continue the setting routine. The zones that have not been
activated do not have to be tested.
Autocheck:
when the setting routine is started the user is informed of the number of
selected pre-check zones that have not been activated since the system was unset and a
warning is sounded; press the
A
or
B
keys to view the zones. These zones must be tested
before setting can be resumed.
Forced Check:
when the setting routine is started the keypad indicates the number of pre-
check zones that are on the system; to view the pre-check zone addresses press
A
or
B
. All
of the preselected zones must be tested before setting can take place.
2=Select Zones
When you select the option, the address and function of the first zone on the system is
displayed. Use
A
or
B
to select a zone,
or enter the zone address directly. To toggle the
status of the pre-check attribute of the zone press
#
. The keypad indicates that the zone is
included in the pre-check by displaying
PRE-CHECK ZONE
. Select other zones to be pre-
checked in the same way. Once all of the zones have been selected, press
esc
.
0 CHECK ZONES
ENT=VIEW
16 CHECK ZONES
A=VIEW