Galaxy Flex Installer Manual
Keypad [58]
159
PA Mode [58.7]
You can programme the PA hotkeys as follows:
1=Instant
The hotkeys activate the PA alarm instantly. This is the default setting.
0=Monitor
Enables the PA hotkeys to be used as a hold-up monitor as described below.
0=Monitor
In this mode the PA hotkeys start a monitor timer (the time period is set using
Hotkey Mon
[51.85]
). If for any reason the user cannot cancel the timer before the end of the monitoring
period a hold-up alarm is signalled.
To start or stop the monitor timer:
Do one of the following:
Press
and
2
at the same time.
Type the Monitor code (user 95), and then press
ent
. (only if this has been enabled
using
Hotkey Mon [51.85]
).
The keypad indicates that the timer has started and displays the remaining time.
If a specific zone input linked to the monitor function is activated. The system must log the
cancelling against the zone number. The Zone Type is 53 = Monitor.
Show Status [58.8]
Enable this option to allow the set status of the groups to be displayed.
To display group set status, press
and
#
together.
F
= Fault
R
= Ready
S
= Set
–
= Group not assigned to keypad
Note:
This option works when the system is set (keypad blank) or unset (normal banner).
It does not operate in engineer mode.
To show the status of the groups individually, press
and
#
again.
To move between each groups, press
and
A
or
and
B
together.
To return to the banner display, press
and
#
again.
Keypad Groups [58.9]
You can assign each keypad to selected groups. The keypad then responds only to user
codes that have a group common to it and only displays alarm information on the groups
assigned.
STATUS 12345678
Groups RRSRSSFS
group block