Program Zones [52]
Galaxy Flex Installer Manual
110
11=RF options
These sub-options are available:
1=Serial No.
The serial number of the wireless detector associated with this zone is
displayed if this already exists. Press
#
to view the serial number in
hexadecimal format. To learn a new detector, program the serial number
manually or use Self-Learn mode.
If you enter the serial number manually, select the device type:
1=Alpha
or
2=V2
. To program a serial number using Self-Learn mode:
1.
Press
instead of typing a serial number.
2.
Insert the battery in the detector and activate the tamper switch. The
serial number of the detector is recorded and displayed for 2 seconds.
If menu option 51.60.8 is enabled a double beep you will hear a
double beep.
If the signal strength is less than 3/10, the message
Signal strength
too low
is displayed for 2 seconds. If menu option 51.60.8 is enabled a
continuous beep is given as a warning.
If there is already an identical serial number on the system, the
message
Zone already allocated
is displayed followed by the zone
details.
If the detector is a multi-loop device, the
2=Loop No
option is
displayed. Enter the loop number.
Note:
If the RF device does not learn, remove the battery, short circuit
the battery terminals, replace the battery and repeat the above
procedure.
2=Loop No.
If the wireless device has multiple inputs (loops) use this option to enter a
loop number from 1 to 6, or 0 if it is a single input device.
3=Supervision
Provides periodic supervision.
0=Disabled
or
1=Enabled
.
4=Auto Reset
Enable to force the zone to close automatically after five seconds if no
close signal is received from the transmitter. This is useful installations
where many motion sensors are activated at the same time.
5=Signal Level
Displays the current signal level of the device.
12=Zone Restoral
Use this attribute to send the restoral event of an individual zone with the trigger event to the
ARC. This is also dependent on global zone restoral. The Restore event trigger must be
enabled in the Alarm Reporting menu
[56.1.2.1.2]
before any restore signals can be sent.
13=Audio Channel
Use this attribute to allocate a zone to an audio channel. More than one zone can be
allocated to the same audio channel.