Outputs [32]
Galaxy Flex Installer Manual
58
Note:
PA, PA Silent, PA Delay, PA Silent Delay and Fire are not included in the test when
is used to include all zones. The response time of the zone circuits is reduced to
20 ms (40 ms for RF RIOs) for the duration of the walk test to detect loose
connections or damaged wiring.
Once the walk test has started, opening a zone (or a zone that is open at the start of the test)
activates outputs programmed as entry/exit horn. If a single zone is open, the keypad
displays the address and function of the zone. If multiple zones are open, the keypad
displays how many zones are open. Use
A
or
B
to view the open zones.
Note:
The Walk Test option does not display the status of the zones. If an open zone is
included in the walk test, the entry/exit horn activates as soon as the test is started
and remains active until the zone is closed.
While the walk test is active the message
WALK TEST ACTIVE / ESC to abort
is
displayed.
Press
#
to view all zones that have been walk tested so far.
To return to the walk test, press
#
again.
Note:
RF zones also record the signal strength in reduced gain mode.
End the walk test
To end the walk test, press
esc
.
The test ends automatically if no zones are activated for 20 minutes.
To view the results of the test, access the event log (refer to
Display Log [22]
). The start of
the walk test is indicated by the
WALK TEST +
message. Each tested zone is recorded (the
activation of each zone is recorded only once during the test, even if it was opened several
times). The end of the test is indicated by
WALK TEST –
.
Outputs [32]
Outputs are tested by function: for example, when you select
01=BELLS
, all outputs
programmed as Bells are activated. Refer to
Program Outputs [53]
for a full description of
each output function.
When you enter the Outputs option, output function type
01=BELLS
is offered for
selection.
Press
A
or
B
to move to the required output function type, or enter the function type number
directly. For example enter
13
to select
SECURITY
.
To test the selected output function press
ent
. Press
ent
to toggle the function ON and OFF
as required.
Users
User types 5 and 6 have access to
01=BELLS
and
02=STROBE
only in the Output option.
Only the engineer has access to all the output types.