Assemble Zone [64]
Galaxy Flex Installer Manual
172
4=Set/Unset
the output is activated by the custom zone when the system is both set and
unset.
Select the output types to be assigned by pressing the
A
and
B
keys or by entering the
number of the required output type, and then assign the required status. When all of the
output types have been selected, press
esc
to return the previous menu level.
For a full list of output types refer to option
Program Outputs [53]
.
Status [64.2]
The Status attribute determines the system conditions under which the custom zone is
operational. The four Status attributes are:
1=Unset
activates an alarm when the system is unset.
2=Entry/Exit
activates an alarm when the system is setting and unsetting.
3=Part Set
activates an alarm when the system is part set.
4=Full Set
activates an alarm when the system is full set.
The default for each of the Status attributes is disabled. To enable the zone to activate an
alarm, select the required Status attribute using the
A
or
B
keys and press
#
. The display
indicates that a custom zone activation, while the system is in the selected Status, will create
an Alarm condition and switch on the assigned outputs.
Note:
The custom zone can be operational in all four status conditions if required.
Setting [64.3]
The Setting attribute determines the function (if any) that the custom zone has in setting and
unsetting the system.
1=Begin Set
if enabled, the custom zone starts the setting procedure.
2=Begin Entry
if enabled, the custom zone starts the unsetting procedure.
3=Sets System
if enabled, the custom terminates the setting procedure.
The default for each of the Setting attributes is disabled. To enable the options, select the
required Setting attribute using the
A
or
B
keys and press the
#
key; the display indicates
that attribute is ENABLED for the custom zone.
Note:
The custom zone can be assigned all three Setting attributes if required, however, it
is recommended that either attribute 1 (Begin Set) or 3 (Sets System) is enabled, but
not both.