Galaxy Flex Installer Manual
Program Zones [52]
109
10=Group
Note:
The Groups attribute is only available if groups have been enabled on the system
(refer to option
Options [63]
).
The Group attribute allows the zone to be assigned to a single group on the system. All
zones default to Group 1.
Press the number of the group to which the zone is to be reassigned, and then press
ent
.
Star (
) Group Function
Certain zone functions have an additional Group attribute feature that allows the other
groups to be affected by their operation.
Press
when allocating the group to the zone.
When you press
the display indicates the group currently assigned to the zone and
prompts for other groups to be added, for example 1
1 – – – – – – –, pressing 4 and 7
assigns 1
1 – – 4 – – 7 –.
Final, Secure Final, Part Final Keyswitch and Push Set Zones
If the star
group feature is assigned a zone programmed as Final, Secure Final, Part Final
or Push Set, then closing the zone when setting multiple groups terminates the setting
procedure for all groups assigned to the zone.
Refer to the zone functions for further information on the operation of this feature.
Exit Zones
The star
group feature can be assigned to a zone programmed as Exit. This allows an Exit
zone to be activated in a group which is not currently being unset without activating an
Intruder alarm condition.
Refer to the zone functions for further information on the operation of this feature.
System Alarms
Flex panels have tamper and alarm monitoring circuits that are not programmable. These
circuits maintain the integrity of the system and all correspond to Group A1.
Zone
Alarm
Description
0001
CUBATT
Control unit battery low
0002
CUAC
Control unit AC fail
0003
LID TAMPER
Control unit lid tamper
0004
AUX TAMPER
Control unit tamper return
Table 5 Control Panel Alarms