![Honeywell Galaxy Flex 100 V3 Скачать руководство пользователя страница 206](http://html.mh-extra.com/html/honeywell/galaxy-flex-100-v3/galaxy-flex-100-v3_installer-manual_153326206.webp)
Appendix B: SIA & contact ID event codes
Galaxy Flex Installer Manual
206
Ev
SIA Event
Log
Log Event
Ev Type Trigger
Contact
Description
Event
Description
ID Event
RX
Manual test
ENG TEST
Engineer test
USER
ALWAYS TR
601
User test
USER TEST
User communications test
USER
ALWAYS TR
601
User test pass
USER TEST P
User test has passed
USER
ALWAYS TR
601
User test fail
USER TEST F
User test has failed
USER
ALWAYS TR
601
S - Sprinkler (Custom SIA - see note 2)
SA
Alarm
Note 1
zone in alarm
ZONE
5.CUS ZON
Note 1
SB
Bypass
OMITTED
zone omitted
ZONE
8.OMIT
573
F
Force omit after rearm
ZONE
8.OMIT
573
SJ
Trouble Rest
LOW RES-
Restor zone resistance
ZONE
15.TROUBL
380
HIGH RES-
Restor zone resistance
ZONE
15.TROUBL
380
SR
Alarm Restore
Note 1
zone restored
ZONE
5.CUS ZON
Note 1
ST
Trouble LOW
RES+
Low resistance on zone
ZONE
15.TROUBL
380
HIGH RES+
High resistance on zone
ZONE
15.TROUBL
380
SU
Unbypass
FORCE OMT-
Unomitted after rearm
ZONE
8.OMIT
573
T - Tamper, Test
TA
Tamper Alarm
Tamper zone alarm
ZONE
9.TAMPER
137
BELL TAMP+
Bell Tamper zone alarm
ZONE
9.TAMPER
137
LID TAMP+
Lid Tamper alarm
ZONE
9.TAMPER
137
AUX TAMP+
Auxiliary Tamper alarm
ZONE
9.TAMPER
137
TAMP S/C+
Tamper short circuit
ZONE
9.TAMPER
383
TAMP O/C+
Tamper open circuit
ZONE
9.TAMPER
383
Module Tamper
MOD
9.TAMPER
145
Missing module alarm
MOD
9.TAMPER
145
CV TAMP+
Voltage tamper on zone
ZONE
9.TAMPER
383
MAX TAMP+
MAX Module Tamper
MOD.
9.TAMPER
145
WALL TAMP
Wall tamper zone alarm
ZONE
9.TAMPER
137
MASK TAMP
ZONE
9.TAMPER
383
DCM EVENT
Invalid Card Tamper alarm
MOD.
9.TAMPER
None
ADDED
Module Added
MOD.
9.TAMPER
531
ENG TAMP+
Engineering Tamper
MISC
9.TAMPER
None
TE
Test End
WALK TEST-
Walk test finished
USER
14.MEN AC
607
TR
Tamper Restor
TAMPER-
Tamper zone restored
ZONE
9.TAMPER
137
18.ZN RESTO
BELL TAMP-
Bell Tamper zone rest.
ZONE
9.TAMPER
137
18.ZN RESTO
LID TAMP-
Lid Tamper restored
ZONE
9.TAMPER
137
18.ZN RESTO
AUX TAMP-
Auxiliary Tamper rest.
ZONE
9.TAMPER
137
18.ZN RESTO
TAMP S/C-
Tamper s/circuit rest.
ZONE
9.TAMPER
383
18.ZN RESTO
TAMP O/C-
Tamper o/circuit rest.
ZONE
9.TAMPER
383
18.ZN RESTO
TAMPER-
Module Tamper rest.
MOD
9.TAMPER
145
18.ZN RESTO
MISSING-
Missing module rest.
MOD
9.TAMPER
145
18.ZN RESTO
CV TAMP-
Voltage tamper rest.
ZONE
9.TAMPER
383
18.ZN RESTO
MAX TAMP-
MAX Module Tamp rest
MOD.
9.TAMPER
145
18.ZN RESTO
ENG TAMP-
Engineer Tamper
MISC
9.TAMPER
None
18.ZN RESTO