![Honeywell Galaxy Flex 100 V3 Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/honeywell/galaxy-flex-100-v3/galaxy-flex-100-v3_installer-manual_153326055.webp)
Galaxy Flex Installer Manual
Access Doors [25]
55
representation of each address. By matching the
(LED off) and
(LED on) on the
keyboard to the LEDs on the MAX, you can identify each device on the system.
Date [25.4]
Use this option to display the events on a specific date. Enter a date using the DD/MM/YY
format.
Access Log
Access events are transmitted using Contact ID, SIA and Alarm Monitoring formats.
Transmitted access events are listed in the table:
Event
Description
SIA
Code
CID
Code
Trigger
Mod
No
User
ID
Access Granted
Valid card presented and validated DG
421
MAX TAGS Yes
Yes
Invalid Card
Card presented has not been
programmed onto system
DD
422
MAX TAGS Yes
No
Card Rejected
Valid card presented, but rejected
for some reason
DK
422
MAX TAGS Yes
Yes
Access log information
The access log contains one of these reasons for the door not operating:
Not Grp Match
Reject Grp Set
Illegal Time
The access log also shows user information:
Press
#
to view the reason for rejection:
Note:
MAX or prox readers’ addresses are different to DCM addresses. For example,
0013, where:
00 = not required
1 = line number 1
3 = address number 3
Access Log print and store option
The Access Doors (MAX Log) is printed online and stored in the event memory.
1021 Grp A1
Reject Grp Set
01:00 THU 26 APR
USER 001 Rejct
DCM address
Reader number
Line Number