![Honeywell Galaxy Flex 100 V3 Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/honeywell/galaxy-flex-100-v3/galaxy-flex-100-v3_installer-manual_153326043.webp)
Galaxy Flex Installer Manual
Override faults and tampers
43
If there are multiple alarm causes and/or multiple groups require to be reset, then the alarm
cause code only has to be entered once. The user enters the most appropriate code as
determined on site. The cause code values should be determined in conjunction with the
Alarm Receiving Centre (ARC).
Override faults and tampers
Whenever a user logs in, the display shows any unrestored faults and tampers. If the
condition cannot be cleared and restored, the user may be able to override the condition.
When a user tries to set the system, any conditions that are present are displayed. The user
can scroll through multiple conditions. If the user has the authority to override the condition,
the following display accompanies the condition:
If the user cannot override the condition,
ENT
to Continue
will not be displayed.
The user can override each authorized condition by pressing
ent
while the condition is
displayed on the keypad. Each condition is individually displayed and overridden.
Pressing
ent
omits the condition for one set period only.
Pressing
esc
returns to the previous banner.
When setting the system with an overridden fault or tamper condition, the display indicates
the overridden function in place of the set mode by showing the omit message as detailed in
the omit menu function. The Override condition is logged, and will last for one set period
only. When all the groups that are affected by the override condition become unset, the
override status is cleared. An override restore is logged at unset.
If, during a setting attempt, there are conditions that haven’t restored and cannot be
overridden, then the system will not set. The display shows the
CALL MANAGER
RESET REQUIRED
banner with a short beep every 30 seconds.
Setting features
The control panel provides a range of features to help the user to set and unset the system.
Show set status
Ensure that Show Status is enabled (refer to
Show Status [58.8]
). Press
and
#
simultaneously to show the group set status.
F
= Fault
R
= Ready
S
= Set
P
= Part Set
N
= Night Set
L
= Locked Out
–
= Group not assigned to keypad
ALERT-BATT LOW
ent=CONTINUE SET
STATUS 12345678
Groups RRSRLPFP
group block