![Honeywell Galaxy Flex 100 V3 Скачать руководство пользователя страница 209](http://html.mh-extra.com/html/honeywell/galaxy-flex-100-v3/galaxy-flex-100-v3_installer-manual_153326209.webp)
Galaxy Flex Installer Manual
Appendix C: SIA event structure
209
Appendix C: SIA event structure
Event
Type
SIA
Level
ACC.
Block
DATA Block Format
(N block code)
Ascii Block Format
(A block code)
Explanation
Zone
3,4
#xxxxxx Ntixx:xx/rixx/EVzzzz
Aeeeeeeeeesiiiiiiii
dddddddddddddddd
Detector alarmed,
keyswitch etc
2
#xxxxxx Ntixx:xx/rixx/EVzzzz
1
#xxxxxx NEVzzzz
0
#xxxx
NEVzzzz
User
3,4
#xxxxxx Ntixx:xx/rixx/iduuu/pixxx/EV Aeeeeeeeeesiiiiiiii
dddddd
User Set/Unset, reset,
duress, etc
2
#xxxxxx Ntixx:xx/rixx/iduuu/pixxx/EV
1
#xxxxxx NEVmmm
0
#xxxx
NEVmmm
Module
3,4
#xxxxxx Ntixx:xx/rixx/pimmm/EV
Aeeeeeeeeesiiiiiiii
ddd
1. With ri modifier:
Set with
A
or
B
key
without code
2. Without ri modifier:
Keypad added, Rio
missing etc
2
#xxxxxx Ntixx:xx/rixx/pimmm/EV
1
#xxxxxx NEVmmm
0
#xxxx
NEVmmm
Event
3,4
#xxxxxx Ntixx:xx/rixx/EV
Aeeeeeeeeesiiiiiiii
1. With ri modifier:
Automatic set, timer
activated
2. Without ri modifier:
Automatic test, engineer
mode
2
#xxxxxx Ntixx:xx/rixx/EV
1
#xxxxxx NEV
0
#xxxx
NEV000
Key
Data Block
ti
Time modifier
ri
Group modifier (not used if groups are
disabled)
id
User modifier
u
User number
pi
Peripheral modifier
m
Peripheral number
EV
Event Code Type (see SIA event list
supplied)
z
Zone number
x
maximum digits for modifier field
Ascii Block
e
Log event (9 chars, see Log Event in table
supplied)
s
Event state ('+' : ON, '-' : OFF, ' ' : NOT
USED)
I
Site identifier (8 char description of site - can
be blank)
d
Descriptor (additional text to describe event),
1. Zone Event - 16 character zone descriptor
2. User Event - 6 character user name
3. Module Event - 3 character module name,
'RIO'
(8 zone module),
'KEY'
(keypad),
'MAX'
(Proximity Reader),
'COM'
(COM1 = Int Telecom, COM4 = Ethernet,
COM5 = GSM/GPRS, COM6 = USB)