![Honeywell Galaxy Flex 100 V3 Скачать руководство пользователя страница 232](http://html.mh-extra.com/html/honeywell/galaxy-flex-100-v3/galaxy-flex-100-v3_installer-manual_153326232.webp)
Appendix G: Peripherals
Galaxy Flex Installer Manual
232
Configuration
The Ethernet module should configure on the data bus automatically. If not, refer to
Connection to the Intellibus
on page 26. The Ethernet module uses DHCP to configure
automatically onto the local area network. If manual setup is required, refer to
[56.3.3]
.
Jumper headers
P3: tamper bypass
Diagnostics
Once powered up the following LEDs can be used to check the status of the module.
LEDs
Network: Ethernet network connection (on when connected)
Ethernet: Active Ethernet communications (flashing)
Intellibus: Panel connection good (short flash every second)
Specifications
Service temperature
-10 deg to +40 deg C
Storage temperature
-10 deg to +60 deg C
Humidity
25% to 55%
Product weight (PCB)
50g
Dimensions (PCB)
L68mm x W80mm x D18mm
Nominal Supply Voltage
15V d.c.
Typical Current
110mA
Maximum Current
135mA
Network Compatibility
100/10 base-T
Encryption
AES128 Bit
Compliance
This product is suitable for use in systems designed to comply with EN50131-
1:2006+A1:2009 and PD6662: 2010. This module complies with the requirements of
EN50136-1-1:1998+A2:2008.
Security Grade – 4
Environmental Class – II
Alarm Transmission System – ATS5=D3, M3, T4, S2, I3
Prevention of substation, according to EN50136-1, is achieved using encryption of account
number and messages to and from the ARC combined with the ability of the CIE to detect
unauthorised removal and addition of devices to the databus.