Galaxy Flex Installer Manual
Display Zones [21, Quick Menu 2]
51
Display options
Display Zones [21, Quick Menu 2]
When you select Display Zones the first zone in the system is displayed. Press
A
or
B
to
display other zones, or enter a zone number directly.
The top line displays:
the address.
Note:
Each camera device on the system is allocated one of these addresses; 8001,
8011, 8021, 8031 or 8041.
the group assigned, if the group mode is enabled. Only the zones assigned to the user’s
group are displayed.
the zone function alternating with the status: open, closed, high resistance, low
resistance, tamper short or tamper open circuit or masked.
The bottom line displays the zone descriptor (if used).
Press
#
to toggle the bottom line information:
If the zone is a hardwired RIO, the circuit resistance in ohms and the RIO (not zone)
voltage is displayed. Press
#
twice to display the maximum (
+
) and minimum (
−
) zone
resistance for a particular day. Use
A
or
B
to scroll through stored values for the past 14
days.
If the zone is an RF zone, the highest and lowest signal strength, and the address of the
RF Portal with which it is communicating is displayed.
Press
to get a printout of all the zones. Press
esc
to abort the printout.
Note:
A printer must be connected to the panel via a printer interface module.
Display Log [22, Quick Menu 3]
Use this option to view the event log. Flex panels can store 1000 events.
The alarm log uses a FIFO (First In, First Out) method to log and store alarms. The control
panel differentiates between mandatory and non-mandatory events. All events are logged,
however, when the log becomes full, non-mandatory events are dropped first. The log will
always contain at least 500 mandatory events (assuming 500 or more mandatory events have
been generated).
A
full list of EN50131-1 mandatory events and non-mandatory events
logged by the panel is given in
Appendix B: SIA & contact ID event codes
.
Note:
The number of events logged from any one source during any set/unset period is
controlled by the
Alarm Limits [51.48]
parameter.
If group mode is enabled (refer to
Options [63]
) and the user code has group choice (refer to
Codes [42]
), the available groups are displayed for selection. Press the number of the groups
to be displayed, the
N
below the selected group changes to a flashing
Y
. When all the