![Honeywell Galaxy Flex 100 V3 Скачать руководство пользователя страница 147](http://html.mh-extra.com/html/honeywell/galaxy-flex-100-v3/galaxy-flex-100-v3_installer-manual_153326147.webp)
Galaxy Flex Installer Manual
Communications [56]
147
User Notify [56.2]
This section defines messages than can be sent directly to an end user’s mobile phone.
1 = Mobile No 1
2 = Mobile No 2
3 = Mobile No 3
4 = SMS Triggers
1 = Intruder
1 = Descriptor
2 = Mode (0 = Disabled, 1 = Enabled)
3 = Phone Sequ.
4 = Groups
2 = Duress
G
3 = Fire
4 = Fault
Each one of these event options
5 = Custom Zones
has the same sub-menus options
as 1 = Intruder
6 = Power
7 = Setting
H
5 = Site ID
Mobile No [56.2.1], [56.2.2] or [56.2.3]
Use these three options to enter three different mobile numbers (22 digits max.) for message
recipients.
SMS Triggers [56.2.4.event]
Use this option to setup the trigger information for any of the event types listed in the menu
structure above.
1=Descriptor
If required you can enter an alternate 16 character description of the
alarm type to help recipient recognition.
2=Mode
Turn the trigger on an off.
3=Phone Sequ.
Define the order in which the three mobile numbers will be used to
transmit the event.
Site ID [56.2.5]
Use this option to enter an ID, which is added to SMS alarm messages to identify the site or
alarm system.