Diagnostics [61]
Galaxy Flex Installer Manual
164
3=RIO Comms
snapshot value from last test.
4=PSU Comms
snapshot value from last test.
5=MAX Comms
snapshot value from last test.
6=COMM Modules
snapshot value from last test.
7=Zones
snapshot value from last test. The
key allows printing of results.
8=DCM Zones
snapshot value from last test.
9=RF Modules
snapshot value from last test.
Timeline [61.2.2]
Use this option to show the time and date of the last check carried out for each of the areas
listed:
1=Batt Size
Battery size in Ah.
2=Batt RF
The battery status of all RF devices. Shows LOW if not OK.
3=PSU Volts
The voltage level of all Smart PSUs in the system including on-
board PSUs.
4=RIO Volts
The voltage level of all Smart PSUs in the system including the on-
board RIOs.
5=Zone Ohms
The current resistance across all zones in the system. For RF zones
signal strength and time since supervision are displayed.
6=Communication
Type of device, address, and the percentage level with all peripherals
in the system.
7=Panel Memory
A check of the panel memory.
9=Batt Volts
Voltage level of the battery connected to the control panel.
Record [61.2.3]
Use this option to start a baseline check of areas 1 to 7 in the table above. You are prompted
to press
to continue with the diagnostic check.
Checks [61.2.4]
Use this option to disable or enable each of the areas 1 to 9 listed above from the baseline
recording.
Print [61.2.5]
Use this option to print the stored baseline data via a print interface module on the RS485
line.
Warnings [61.3]
This shows working items that are close to a failure status. You can view the following: