Program Zones [52]
Galaxy Flex Installer Manual
108
7=Custom SIA
Use this option to change a zone’s SIA mnemonic. The default is the standard SIA
mnemonic for each zone type.
The customisable mnemonics are shown in the following table:
No
Event text
Description
Alarm Closed Omit Unomit Troub ResTr.
Test Tamp
01
Default
02
AT/R Power
AC Trouble, AC Restoral
AT
AR
BB
BU
BT
BJ
BX
TA
03
BA/R Burglary Burglary Alarm, Burglary Restoral
BA
BR
BB
BU
BT
BJ
BX
TA
04
DG/D Access Access Granted, Access Denied
DG
DD
BB
BU
DT
DJ
BX
TA
05
FA/R Fire
Fire Alarm, Fire Restoral
FA
FR
FB
FU
FT
FJ
FX
TA
06
GA/R Gas
Gas Alarm, Gas Restoral
GA
GR
GB
GU
G
GJ
GX TA
07
HA/R Holdup Holdup Alarm, Holdup Restoral
HA
HR
HB
HU
HT
HJ
BX
TA
08
KA/R Heat
Heat Alarm, Heat Restoral
KA
KR
KB
KU
KT
KJ
BX
TA
09
LT/R Line Fail Line Trouble, Line Restoral
LT
LR
BB
BU
BT
BJ
BX
TA
10
MA/R Medical Medical Alarm, Medical Restoral
MA
MR
MB
MU
MT
MJ
BX
TA
11
PA/R Panic
Panic Alarm, Panic Restoral
PA
PR
PB
PU
PT
PJ
BX
TA
12
QA/R Assist
Emergency Alarm, Emergency Restoral QA
QR
QB
QU
QT
QJ
BX
TA
13
RO/C Relay
Relay Open, Relay Closed
RO
RC
BB
BU
BT
BJ
BX
TA
14
SA/R Sprinklr Sprinkler Alarm, Sprinkler Restoral
SA
SR
SB
SU
ST
SJ
BX
TA
15
TA/R Tamper Tamper Alarm, Tamper Restoral
TA
TR
TB
TU
BT
BJ
TX
TA
16
WA/R Water
Water Alarm, Water Restoral
WA
WR
WB
WU
WT
WJ
BX
TA
17
YT/R Battery
Battery Alarm, Battery Restoral
YT
YR
BB
BU
BT
BJ
BX
TA
18
ZA/R Freezer Freezer Alarm, Freezer Restoral
ZA
ZR
ZB
ZU
ZT
ZJ
BX
TA
19
UA/R Keysafe Keysafe opened, Keysafe closed
UA
UR
UB
UU
UT
UJ
BX
TA
Table 4 Customisable Mnemonics
Note:
If two zones, programmed as Custom SIA (with the same type assigned, e.g. both
WA/R) activate within the confirm time window in SET or UNSET condition, a
CONFIRM is logged.
8=Activity Mon.
Use this attribute to check a zone’s activity during a set time period or set/unset cycle. The
options are:
0=None
(default),
1=Type1
,
2=Type2
,
3=Type3
,
4=Type4
,
5=Type5
,
6=Type6
If the zone does not activate at least once within the programmed criteria a zone masked
fault is indicated at the panel. The fault is logged as a masked event indicating that the zone
has been inactive for the programmed period. Refer to
Activity Monitoring [51.61]
.
9=Res. Select
See
Resistance Select [51.46]
.