![Honeywell Galaxy Flex 100 V3 Скачать руководство пользователя страница 207](http://html.mh-extra.com/html/honeywell/galaxy-flex-100-v3/galaxy-flex-100-v3_installer-manual_153326207.webp)
Galaxy Flex Installer Manual
Appendix B: SIA & contact ID event codes
207
Ev
SIA Event
Log
Log Event
Ev Type Trigger
Contact
Description
Event
Description
ID Event
TS
Test Start
WALK TEST+
Walk test started
USER
14.MEN AC
607
ARC TEST
TEST
ALWAYS TR
607
V -??
V Y
PRINT OC
USER
NONE
0
PRINT OL
MISC
NONE
0
W - Water(Custom SIA - see note 2)
WA Alarm
Note 1
zone in alarm
ZONE
5.CUS ZON
Note 1
WB Bypass
OMITTED
zone omitted
ZONE
8.OMIT
573
F
Force omit after rearm
ZONE
8.OMIT
573
WJ
Trouble Rest
LOW RES-
Restor zone resistance
ZONE
15.TROUBL
380
HIGH RES-
Restor zone resistance
ZONE
15.TROUBL
380
WR
Alarm Restore
Note 1
zone restored
ZONE
5.CUS ZON
Note 1
18.ZN RESTO
WT
Trouble
LOW RES+
Low resistance on zone
ZONE
15.TROUBL
380
HIGH RES+
High resistance on zone
ZONE
15.TROUBL
380
WU Unbypass
FORCE OMT-
Unomitted after rearm
ZONE
8.OMIT
573
X - RF
XQ
RF Jam
RF JAM+
RF Signal Jammed
MOD
15.TROUBLE
344
XT
RF Batt Low
RF
RF Battery Low
ZONE
13.ELEC ST
384
15.TROUBLE
XH
RF Jam Restore
RF JAM-
RF Jam Restore
MOD
15.TROUBLE
344
XR
RF Batt Lo Rst
RF BATLOW-
RF Battery Low Restore
ZONE
13.ELEC ST
384
15.TROUBLE
Y
YC
Comms Fail
internal to tel
Tel module lost RS485
EVENT
ALWAYS TR
350
YF
Panel Cold Start
MEM RESET
Power Up Panel
MISC
13.ELEC ST
None
YK
Comm Restoral
internal to tel
Tel module rest. RS485
EVENT
ALWAYS TR
350
YL
+AC+ Batt Fail
+AC+BATT
Mains fail and batt low
EVENT
13.ELEC ST
None
YP
PSU fail
PSU FLT+
Power Supply Unit fault
EVENT
13.ELEC ST
314
YR
Sys Batt Rest.
BATT LOW-
Battery Low restored
ZONE
13.ELEC ST
302
CU BATT-
Control unit batt restore
ZONE
13.ELEC ST
302
BATT LOW-
Mod Battery Low rest
MOD
13.ELEC ST
302
BATT.FLT-
Battery fault restored
MOD
13.ELEC ST
302
YT
Sys Batt Troub
BATT LOW+
Battery Low
ZONE
13.ELEC ST
302
CU BATT+
Control unit Battery Low
ZONE
13.ELEC ST
302
BATT LOW+
Module Battery Low
MOD
13.ELEC ST
302
BATT.FLT+
Battery fault
MOD
13.ELEC ST
302
FUSE A2P
MOD
13.ELEC ST
302
Z - Freezer (Custom SIA - see note 2)
ZA
Alarm
Note 1
zone in alarm
ZONE
5.CUS ZON
Note 1
ZB
Bypass
OMITTED
zone omitted
ZONE
8.OMIT
573
F
Force omit after rearm
ZONE
8.OMIT
573
ZJ
Trouble Rest
LOW RES-
Restor zone resistance
ZONE
15.TROUBL
380
HIGH RES-
Restor zone resistance
ZONE
15.TROUBL
380
ZR
Alarm Restore
Note 1
zone restored
ZONE
5.CUS ZON
Note 1
18.ZN RESTO
ZT Trouble
LOW RES+
Low resistance on zone
ZONE
15.TROUBL
380
HIGH RES+
High resistance on zone
ZONE
15.TROUBL
380
ZU Unbypass
FORCE OMT-
Unomitted after rearm
ZONE
8.OMIT
573