![Honeywell Galaxy Flex 100 V3 Скачать руководство пользователя страница 120](http://html.mh-extra.com/html/honeywell/galaxy-flex-100-v3/galaxy-flex-100-v3_installer-manual_153326120.webp)
Program Outputs [53]
Galaxy Flex Installer Manual
120
The valid keypad addresses and the respective output addresses are indicated in the
following table:
Line
Address
Output Addresses
1
0 – 7
10 – 17
Table 7 Addresses of Valid Keypad Outputs
Attributes
Use
A
or
B
to step through the attributes, or enter an attribute number (1 to 7). Once the
required attribute is on display, press
ent
to gain access.
Once the attribute has been assigned press
ent
to save the programming and return to the
attribute selection level. Press
esc
at any time when assigning attributes to abort
programming and return to the attribute selection level.
1=Output Function
The Output Function attribute displays the address and the current function of the selected
output along with the output function reference number. You can scroll through the output
functions or you can enter an output function number directly, for example, enter 16 to
display output function
16=FIRE
.
Once the required output function is displayed, press
ent
to assign it to the output.
2=Output Mode
Each output function defaults to a specific, logical output mode. However, the output mode
of each function can be modified to meet special requirements: when reprogrammed, the
new mode applies to all outputs assigned to that function. The output modes are:
1=Latch
the output remains active until a valid code is entered.
2=Reflex
the output follows the activity of the triggering event, for example, the Set
output follows the setting and unsetting of the group.
3=Pulse
the output remains active for the programmed pulse time of 1 to 3000 seconds
(50 minutes).
3=Output Polarity
Use this attribute to set the normal operational state of the output. All outputs are referred to
having positive (0=POS) or negative (1=NEG) polarity. An output programmed as positive
polarity is 12 V in the normal condition and goes to 0 V when activated. A negative polarity
output goes from the normal condition of 0 V to 12 V in the active state. All outputs except
SET (09) default to positive output mode.
Note:
The Switch DC output is a positive polarity output, however, the normal condition is
0 V going to 12 V when activated. The output mode is normally Pulse.