![Honeywell Galaxy Flex 100 V3 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/honeywell/galaxy-flex-100-v3/galaxy-flex-100-v3_installer-manual_153326022.webp)
Install peripheral devices
Galaxy Flex Installer Manual
22
Using the keypad:
1.
Press any key. The following is displayed:
2.
Select your language, and then press
ent
. The following is displayed:
3.
Select the default set to load, and then press
ent
. There are country defaults from which
to choose.
4.
Enter Engineer Mode (for instructions see
Engineer Mode
on page 37). Any
outstanding faults or alarm conditions will be displayed if present. Press
ent
to accept
these.
5.
Set the time and date (
41 ent
).
6.
If you are splitting your system into groups, enable groups now, before performing any
other programming (
63 ent 1 ent 1 ent
).
7.
Select Auto Detect (
72 ent
).
In this mode the system automatically recognises any additional peripheral devices you
add to the system.
Install peripheral devices
Peripheral data buses
The panel has the following data buses:
RS485 bus
– this is used for all peripheral devices except cameras and communications
modules.
Intellibus
– this is used for cameras and communication modules only. The Intellibus
operates at a higher speed, which is required for video image transmission.
Data bus cabling
For details on the wiring topology see the following page. It is possible to run both Intellibus
and RS485 bus cores within the same cable. If you use this method do not run data out and
then back in the same cable.
We strongly recommend you use a twisted-pair cable (Cat 5/5e). However, for cable
runs of less than 100 m in normal environments, standard 4-core cable can be used.
Defaults
1=UK
Language
1=English