![Honeywell Galaxy Flex 100 V3 Скачать руководство пользователя страница 124](http://html.mh-extra.com/html/honeywell/galaxy-flex-100-v3/galaxy-flex-100-v3_installer-manual_153326124.webp)
Program Outputs [53]
Galaxy Flex Installer Manual
124
Zone Function
Output Functions
Fire
Horn
E/E
Horn
Part
Set
Confirm Line
Fail
Video Comm
Fail
DLYD
Fire
No
Re-arm
Timer-A Timer-B
16
17
18
19
20
21
22
23
27
28
29
30
01
Final
–
S
SXE
–
-
–
S
–
–
S
–
–
02
Exit
–
S
SXE
–
S
–
S
–
–
S
–
–
03
Intruder
–
S
SXE
–
S
–
S
–
–
S
–
–
05
Security
–
S
A
–
–
–
S
–
–
S
–
–
07
Entry
–
S
SXE
–
-
–
S
–
–
S
–
–
08
Push Set
–
–
X
–
–
–
–
–
–
–
–
–
09
Keyswitch
–
–
–
X
–
–
–
–
–
–
–
–
10
Secure Final
–
A
A
X
S
–
S
–
–
S
–
–
11
Part Final
–
A
SXE
X
S
–
S
–
–
S
–
–
12
Part Entry
–
A
XE
–
S
–
S
–
–
S
–
–
13
PA
–
A
–
–
–
–
–
–
–
A
–
–
14
PA Silent
–
–
–
–
–
–
–
–
–
–
–
–
15
PA Delay
–
A
A
–
–
–
–
–
–
A
–
–
16
PA Delay Silent
–
–
–
–
–
–
–
–
–
–
–
–
18
Spare
–
–
–
–
–
–
–
–
–
–
–
–
19
Fire
A
A
A
–
–
–
V
–
A
A
–
–
20
Tamper
–
A
A
–
–
–
S
–
–
S
–
–
22
Beam Pair
–
S
SXE
–
–
–
S
–
–
S
–
–
23
Battery Low
–
–
–
–
–
–
–
–
–
–
–
–
24
Line Fail
–
–
U
–
–
A
–
–
–
–
–
–
25
AC Fail
–
–
–
–
–
–
–
–
–
–
–
–
26
Log
–
–
–
–
–
–
–
–
–
–
–
–
28
Video
–
S
SXE
–
S
–
S
–
–
S
–
–
29
Video Exit
–
S
SXE
–
S
–
S
–
–
S
–
–
32
Set Log
–
–
–
–
–
–
–
–
–
–
–
–
33
Custom-A
?
?
?
?
?
?
?
?
?
?
?
?
34
Custom-B
?
?
?
?
?
?
?
?
?
?
?
?
39
Keyswitch Reset
–
–
–
–
–
–
–
–
–
–
–
–
40
Bell fail
–
–
–
–
–
–
–
–
–
–
–
–
41
Intr Low
–
S
SXE
–
S
–
S
–
–
S
–
–
42
Intr High
–
S
SXE
–
S
–
S
–
–
S
–
–
43
PSU Fault
–
–
–
–
–
–
–
–
–
–
–
–
44
Fault
–
–
–
–
–
–
–
–
–
–
–
–
45
Entry 2
-
S
SXE
-
-
-
S
-
-
S
-
-
53
Monitor
-
-
-
-
-
-
-
-
-
-
-
-
Key:
S
Activates when system is Set
?
Activation dependant on system programming
P
Activates when system is Part Set
X
Activates during Exit Time
U
Unset
E
Activates during Entry Time
A
Activated in any condition
L
Switches output off if linked to destination output
–
No effect
T
Activates if zone resistance is less than value for
tamper s/c or greater than value for tamper o/c
O
Activates when zone is omitted