![Honeywell Galaxy Flex 100 V3 Скачать руководство пользователя страница 103](http://html.mh-extra.com/html/honeywell/galaxy-flex-100-v3/galaxy-flex-100-v3_installer-manual_153326103.webp)
Galaxy Flex Installer Manual
Parameters [51]
103
User Test [51.84]
Use this option to enable the comm. test facility via the keypad hotkey
and
0
. This allows
the user to activate a comms test to the ARC. There are two options:
0=Disabled
,
1=Enabled
.
When the comms test is started by the user the system will try to transmit a test message to
the ARC via the normal programmed receiver sequence. If the message is received
successfully a double beep is given on the keypad buzzer to confirm successful
transmission.
HU Monitor [51.85]
Use this option to set the Holdup monitor timer duration, and to program user code 95 so it
can be used to start and stop the timer.
1=Timer Duration
Set the monitor time period between 1 and 3,600 seconds. The default
value is 50 seconds.
2=User95 as Mon.
User code 95 can be used to start or stop the monitor timer. The
default is disabled.
Auto Reset [51.86]
When this option is enabled, the panel forces a reset 30 seconds after an alarm is cancelled
by a user.
Omit Signal [51.87]
Use this option to control the transmission of omit events via reporting.
0=Disabled
No omits are signalled.
1=Auto Only
signals automatically generated omits only, e.g. auosets or rearms.
2=All Events
Signals automatically and manually generated omits.
Silent Eng. [51.88]
Use this option to disable sounders in engineering mode and force the panel to restart in
normal mode after one hour if left in engineer mode. The one-hour timer will not be started
if the panel lid is left open.
Patrol Code [51.89]
The Patrol Code, when enabled, has no access to
Users [42]
. The Patrol Code can set/unset
groups and reset all alarms in those groups, and has access to the event and access logs.
Note:
Use of the Patrol Code reduces the number of available user codes by one. The user
immediately before the Manger code will be reserved for the Patrol code
There are two options:
0=Disabled
,
1=Enabled
.