Additional programming
Galaxy Flex Installer Manual
30
Program outputs (53 ent + Output Address)
Output Function (
1 ent
) – assign an output type
Descriptor (
5 ent
) – name an output (up to 12 characters)
Output Mode (
2 ent
) – access these options:
Latch (
1 ent
) – output active unlit a valid code entered
Reflex (
2 ent
) – output follows activity of trigger event
Pulse (
3 ent
) – output remains active for a programmed pulse time
Output Groups (
7 ent
) – assign groups to the output
Control via TouchCenter (
6 ent 1 ent
) – set which outputs are controllable from the
TouchCenter
Output Polarity (
3 ent
) – switch polarity (the default is positive, switches from +12 V
to 0 V when activated)
Communication (56 ent)
Where applicable, for each module type (
1
to
8 ent
):
Select format
Select trigger events or channels to enable
Set account number
Set phone number/IP addresses
Set up autotest frequency
Perform an engineer test
Timers (65 ent)
Weekly Schedule (
1 ent
) – assign schedules to required functions
Autoset (groups) (
3 ent
) – select a schedule for each group
Timer Outputs (
2 ent
) – enable timers and assign weekly schedules.
Users and access templates
If full time-controlled access control is required, allocate an access template to every user.
An access template is a list of groups and time schedules that provides access to multiple
areas and at many set times with only one programming step. This reduces programming
time and complexity.
The Access Template to be used for each user is chosen within each user’s options in the
Template menu (
42 ent 1 ent 9 ent
).
Access Templates are programmed in the Access Templates menu (
45 ent 6 ent
), and are
fully customisable. In each Access Template, each group must be allocated a time schedule.