Galaxy Flex Installer Manual
Assemble Zone [64]
173
Log [64.4]
This attribute determines which custom zone activations are logged. On selecting Log the
current selection is displayed. To change the selection press the # key, this toggles between
the Log options:
Disabled
the custom zone activations are not logged.
Entry/Exit
the custom zone activations only log during the setting and unsetting
procedure.
24 Hours
all custom zone activations log (both in the set and unset states).
Alarms
the custom zone only logs when an activation results in an alarm condition.
Note:
The opening (+) and closing (–) of custom zones are recorded in the event log.
Assemble Zone Example
Assemble a zone that:
Activates Bells outputs when the system is set.
Activates Link-A outputs when the system is unset.
Generates an alarm condition when the system is part and full set.
Does not generate an alarm condition during the setting and unsetting procedure.
Acts as a terminator when the system is setting.
Logs all activation (in both set and unset states).
To program Assemble Zone:
(Assuming factory default settings)
1.
Select option
64=ASSEMBLE ZONES
, and then press
ent
.
2.
Select custom zone (1=Custom-A, 2=Custom-B), press
ent
.
Outputs
is displayed.
3.
Press
ent
to select this option.
01=Bells
is displayed.
4.
Press
#
.
Set
is displayed.
5.
Type 51. Link-A
is displayed. Press
#
.
Set
is displayed.
6.
Press
#
.
Unset
is displayed.
7.
Press
esc
.
Outputs
is displayed.
8.
Press
A
.
Status
is displayed.
9.
Press
ent
to select this option.
Unset Disabled
is displayed.
10.
Press
A
.
Entry/ Exit Disabled
is displayed.
11.
Press
A
.
Part Set Disabled
is displayed.
12.
Press
#
.
Part Set Alarm
is displayed.