
124
REQUIRED REAGENTS & APPARATUS (Using Powder Pillows)
Quantity Required
Description
Per Test
Unit
Cat. No.
DPD Free Chlorine Powder Pillows, 10 mL.................................. 1 pillow .. 100/pkg21055-69
Sample Cell, 10, 20, 25 mL, w/ cap...........................................................2 ....... 6/pkg24019-06
REQUIRED REAGENTS & APPARATUS (Using AccuVac Ampuls)
DPD Free Chlorine Reagent AccuVac Ampuls .............................1 ampul ..... 25/pkg25020-25
Beaker, 50 mL ...........................................................................................1 .........each 500-41H
OPTIONAL REAGENTS
Description
Unit
Cat. No.
Chlorine Standard Solution, PourRite ampule, 25-30 mg/L, 2 mL ....... 20/pkg......... 26300-20
DPD Free Chlorine Reagent, SwifTest ................................................ 250 tests.......... 28023-00
Potassium Iodide Solution, 30 g/L ............................................ 100 mL
*
MDB............. 343-32
Sodium Arsenite, 5 g/L .............................................................100 mL* MDB ............ 1047-32
Sodium Hydroxide Standard Solution, 1.000 N .......................100 mL* MDB........... 1045-32
Sulfuric Acid Standard Solution, 1.000 N .................................100 mL* MDB........... 1270-32
Water, deionized............................................................................................ 4 L .............. 272-56
OPTIONAL APPARATUS
AccuVac Snapper Kit.................................................................................. each......... 24052-00
Cylinder, graduated, 25 mL ....................................................................... each.............. 508-40
pH Meter,
sens
ion
™
1
, portable, with electrode .......................................... each .......... 51700-10
pH Paper, 1 to 11 pH units ................................................................ 5 rolls/pkg.............. 391-33
Pipet, TenSette, 0.1 to 1.0 mL .................................................................... each .......... 19700-01
Pipet Tips, for 19700-01 TenSette Pipet ................................................ 50/pkg..21856-96Pipet
Tips, for 19700-01 TenSette Pipet ..................................................... 1000/pkg.......... 21856-28
PourRite Ampule Breaker........................................................................... each......... 24846-00
For Technical Assistance, Price and Ordering
In the U.S.A.—Call 800-227-4224
Outside the U.S.A.—Contact the Hach office or distributor serving you.
* Marked Dropper Bottle - contact Hach for larger sizes.
CHLORINE, FREE
continued
Содержание DR/850
Страница 2: ...2...
Страница 8: ...8...
Страница 9: ...9 Sample Procedure Explained...
Страница 10: ...10 Sample Procedure Explained continued...
Страница 11: ...11 Sample Procedure Explained continued...
Страница 12: ...12 Sample Procedure Explained continued...
Страница 41: ...41 CHEMICAL ANALYSIS INFORMATION continued Figure 10 Multiple Standard Additions Graph...
Страница 69: ...69 SECTION 4 PROCEDURES...
Страница 70: ...70...
Страница 92: ...92...
Страница 100: ...100...
Страница 108: ...108...
Страница 116: ...116...
Страница 139: ...139...
Страница 140: ...140...
Страница 168: ...168...
Страница 176: ...176...
Страница 184: ...184...
Страница 194: ...194...
Страница 202: ...202...
Страница 214: ...214...
Страница 234: ...234...
Страница 242: ...242...
Страница 264: ...264...
Страница 270: ...270...
Страница 284: ...284...
Страница 298: ...298...
Страница 314: ...314...
Страница 324: ...324...
Страница 332: ...332...
Страница 336: ...336...
Страница 340: ...340...
Страница 354: ...354...
Страница 370: ...370...
Страница 378: ...378...
Страница 386: ...386...
Страница 398: ...398...
Страница 404: ...404...
Страница 412: ...412...
Страница 424: ...424...
Страница 436: ...436...
Страница 446: ...446...
Страница 456: ......
Страница 459: ......
Страница 460: ...460...