![background image](http://html1.mh-extra.com/html/delta/asd-b2-1521-f/asd-b2-1521-f_user-manual_2474519035.webp)
Chapter 2 Installation
ASDA-B2
2-14
Revision May, 2018
Servo Drive
(kW)
Servo Motor
Rotor Inertia
J (× 10
-4
kg.m
2
)
Regenerative
power from empty
load 3000r/min to
stop
Eo (joule)
Max.
regenerative
power of
capacitance
Ec(joule)
Medium
Inertia
3.0
ECMA-E
△
1830
54.95 217.73
28
ECMA-F
△
1830
54.95 217.73
28
ECMA-E
△
1835
54.95 217.73
28
Medium-high
Inertia
1.0 ECMA-F
△
1308
13.6 67.25 18
2.0 ECMA-F
△
1313
20.0 98.90 21
2.0 ECMA-F
△
1318
24.9 123.13 21
3.0 ECMA-F
△
1830
54.95 217.73
28
High
Inertia
0.4
ECMA-G
△
1303
8.17
40.40
8
0.75
ECMA-G
△
1306
8.41
41.59
14
1.0
ECMA-G
△
1309
11.18
55.29
18
Eo = J x wr
2
/182 (joule), Wr : r/min
Assume that the load inertia is N times to the motor inertia and the motor decelerates
from 3000r/min to 0, its regenerative energy is (N+1) x Eo. The consumed regenerative
resistor is (N+1) × Eo - Ec
joule
.
If the cycle of back and forth operation is T sec, then
the power of regenerative resistor it needs is 2× ((N+1) x Eo - Ec) / T.
Followings are the calculation procedure:
Step
Procedure
Calculation and Setting Method
1
Set the capacity of regenerative
resistor to the maximum
Set P1-53 to the maximum value
2
Set T cycle of back and forth
operation
Enter by the user
3
Set the rotational speed wr
Enter by the user or read via P0-02
4
Set the load/motor inertia ratio N
Enter by the user or read via P0-02
5
Calculate the maximum
regenerative energy Eo
Eo= J * wr
2
/182
6
Set the absorbable regenerative
energy Ec
Refer to the above table
7
Calculate the needful capacitance
of regenerative resistor
2 x ((N+1) x Eo
–
Ec) / T
Take 400W as the example, the cycle of back and forth operation is T = 0.4sec, the
maximum speed is 3000r/min and the load inertia is 7 times to the motor inertia. Then,
the needful power of regenerative resistor is 2 × ((7+1) × 1.68
–
8) / 0.4 = 27.2 W. If it is
smaller than the built-in capacity of regenerative resistor, the built-in 60W regenerative
Содержание ASD-B2-1521-F
Страница 1: ......
Страница 20: ...ASDA B2 Chapter 1 Installation and Model Explanation Revision May 2018 1 7 1 4 Servo Drive Features...
Страница 81: ...Chapter 3 Wiring ASDA B2 3 42 Revision May 2018 This page is intentionally left blank...
Страница 103: ...Chapter 5 Trial Operation and Tuning ASDA B2 5 12 Revision May 2018 5 5 2 Inertia Estimation Flowchart with Mechanism...
Страница 124: ...ASDA B2 Chapter 6 Control Modes of Operation Revision May 2018 6 13...