Chapter 6 Control Modes of Operation
ASDA-B2
6-18
Revision May, 2018
P1-36
TSL
Acceleration / Deceleration Constant of
S-curve
Address: 0148H
0149H
Operation
Interface:
Panel/Software
Communication
Related Section:
Section 6.3.3
Default:
0
Control
Mode:
S
Unit: ms
Range: 0 ~ 10000 (0: Disabled)
Data Size: 16-bit
Display
Format:
Decimal
Settings: Acceleration / Deceleration Constant of S-Curve:
P1-34: Set the acceleration time of acceleration / deceleration of
trapezoid-curve
P1-35: Set the deceleration time of acceleration / deceleration of
trapezoid-curve
P1-36: Set the smoothing time of S-curve acceleration and
deceleration
P1-34, P1-35, and P1-36 can be set individually.
NOTE
When the source of speed command is analog, and P1-36 is set
to 0, it will disable S-curve function.
Analog Speed Command Filter
Analog speed command filter is provided especially for ASDA-B2 series users.
It mainly helps with buffer when the analog input signal changes too fast.
Speed (rpm)
3000
-3000
0
1
3
2
4
6
5
7
9
8
Time (sec)
Motor Torque
Analog speed command
Содержание ASD-B2-1521-F
Страница 1: ......
Страница 20: ...ASDA B2 Chapter 1 Installation and Model Explanation Revision May 2018 1 7 1 4 Servo Drive Features...
Страница 81: ...Chapter 3 Wiring ASDA B2 3 42 Revision May 2018 This page is intentionally left blank...
Страница 103: ...Chapter 5 Trial Operation and Tuning ASDA B2 5 12 Revision May 2018 5 5 2 Inertia Estimation Flowchart with Mechanism...
Страница 124: ...ASDA B2 Chapter 6 Control Modes of Operation Revision May 2018 6 13...