Chapter 4 Panel Display and Operation
ASDA-B2
4-10
Revision May, 2018
4.4.4 Digital Input Diagnosis Operation
Enter into the Digital Input Diagnosis Mode by the following setting methods. When the
external output signal DI1 ~ DI9 is ON, the corresponding signal will be shown on the
panel. It is displayed by bit. When it shows bit, it means it is ON.
For example, if it shows
1E1
,
E
is in hexadecimal format, it will be
1100
when it transfers
to binary format. Then, DI6 ~ DI8 is ON.
(Hexadecimal Display)
4.4.5 Digital Output Diagnosis Operation
Enter into the Digital Output Diagnosis Mode by the following setting methods. The output
signal DO1 ~ DO6 is ON and the corresponding signal will be shown on the panel. It is
displayed by bit. When it shows bit, it means it is ON.
For example, if it shows
3F
,
F
is in hexadecimal format, it will be
1111
when it transfers to
binary format. Then, DO1 ~ DO4 is ON.
(Hexadecimal Display)