Chapter 7 Parameters
ASDA-B2
7-66
Revision May, 2018
P2-35
PDEV
Condition of Excessive Position Control
Deviation Warning
Address: 0246H
0247H
Operation
Interface:
Panel/Software
Communication
Related Section: N/A
Default:
480000
Control
Mode:
PT
Unit: pulse
Range: 1 ~ 16000000
Data Size: 32-bit
Format: Decimal
Settings: The setting of excessive position control deviation warning in
servo drive error display (P0-01).
P2-36
DI9 Extended EDI9 Functional Planning
Address: 0248H
0249H
Operation
Interface:
Panel/Software
Communication
Related Section:
Table 7.1
Default:
0
Control
Mode:
ALL
Unit: N/A
Range: 0 ~ 0x015F
(The last two codes are EDI code)
Data Size: 16-bit
Format: Hexadecimal
Settings:
Input function selection: Please refer to table 7.1
Input contact: a or b contact
0: Set the input contact as normally closed (b contact)
1: Set the input contact as normally opened (a contact)
Input function selection
Input contact
Not in use
Содержание ASD-B2-1521-F
Страница 1: ......
Страница 20: ...ASDA B2 Chapter 1 Installation and Model Explanation Revision May 2018 1 7 1 4 Servo Drive Features...
Страница 81: ...Chapter 3 Wiring ASDA B2 3 42 Revision May 2018 This page is intentionally left blank...
Страница 103: ...Chapter 5 Trial Operation and Tuning ASDA B2 5 12 Revision May 2018 5 5 2 Inertia Estimation Flowchart with Mechanism...
Страница 124: ...ASDA B2 Chapter 6 Control Modes of Operation Revision May 2018 6 13...