ASDA-B2
Chapter 6 Control Modes of Operation
Revision May, 2018
6-47
MON2 is motor torque analog output)
MON1 output voltage= 8 ×
Motor speed
(unit: Volts)
(Max. motor speed ×
P1-04
)
100
MON2 output voltage= 8 ×
Motor toque
(unit: Volts)
(Max. motor torque ×
P1-05
)
100
P4-20
DOF1
Offset Adjustment Value of Analog
Monitor Output (MON1)
Address: 0428H
0429H
Operation
Interface:
Panel / Software
Communication
Related Section:
Section 6.4.4
Default:
Factory setting
Control
Mode:
ALL
Unit: mV
Range: -800 ~ 800
Data Size: 16-bit
Display
Format:
Decimal
Settings: Offset adjustment value (cannot reset)
P4-21
DOF2
Offset Adjustment Value of Analog
Monitor Output (MON2)
Address: 042AH
042BH
Operation
Interface:
Panel / Software
Communication
Related Section:
Section 6.4.4
Default:
0
Control
Mode:
ALL
Unit: mV
Range: -800 ~ 800
Data Size: 16-bit
Display
Format:
Decimal
Settings: Offset adjustment value (cannot reset)
Содержание ASD-B2-1521-F
Страница 1: ......
Страница 20: ...ASDA B2 Chapter 1 Installation and Model Explanation Revision May 2018 1 7 1 4 Servo Drive Features...
Страница 81: ...Chapter 3 Wiring ASDA B2 3 42 Revision May 2018 This page is intentionally left blank...
Страница 103: ...Chapter 5 Trial Operation and Tuning ASDA B2 5 12 Revision May 2018 5 5 2 Inertia Estimation Flowchart with Mechanism...
Страница 124: ...ASDA B2 Chapter 6 Control Modes of Operation Revision May 2018 6 13...