ASDA-B2
Chapter 7 Parameters
Revision May, 2018
7-55
P2-10
DI1 DI1 Funcitonal Planning
Address: 0214H
0215H
Operation
Interface:
Panel/Software
Communication
Related Section:
Table 7.1
Default:
101
Control
Mode:
ALL
Unit: N/A
Range: 0 ~ 0x015F
(The last two codes are DI code)
Data Size: 16-bit
Format: Hexadecimal
Settings:
Input funciton selection: Please refer to table 7.1
Input contact: a or b contact
0: Set the input contact as normally closed (b contact)
1: Set the input contact as normally opened (a contact)
(P2-10 ~ P2-17 and P2-36) The setting value of function
programmed
When parameters are modified, please re-start the servo drive
to ensure it can work normally.
Note: Parameter P3-06 is used to set how digital inputs (DI)
accepts commands, through external terminal or the
communication which determined by P4-07.
P2-11
DI2 DI2 Funcitonal Planning
Address: 0216H
0217H
Operation
Interface:
Panel/Software
Communication
Related Section:
Table 7.1
Default:
104
Control
Mode:
ALL
Unit: N/A
Range: 0 ~ 0x015F
(The last two codes are DI code)
Data Size: 16-bit
Format: Hexadecimal
Settings: Please refer to the description of P2-10
Input function selection
Input contact
Not in use
Содержание ASD-B2-1521-F
Страница 1: ......
Страница 20: ...ASDA B2 Chapter 1 Installation and Model Explanation Revision May 2018 1 7 1 4 Servo Drive Features...
Страница 81: ...Chapter 3 Wiring ASDA B2 3 42 Revision May 2018 This page is intentionally left blank...
Страница 103: ...Chapter 5 Trial Operation and Tuning ASDA B2 5 12 Revision May 2018 5 5 2 Inertia Estimation Flowchart with Mechanism...
Страница 124: ...ASDA B2 Chapter 6 Control Modes of Operation Revision May 2018 6 13...