AL026:
Unreliable internal data of the encoder
Causes
Checking Method
Corrective Actions
The encoder is in
error.
(Errors occur in the
internal data for three
times continuously)
1. Check if the servo is properly
grounded.
2. Check if the encoder cable
separates from the power
supply or the high-current circuit
to avoid the interference.
3. Check if the shielding cables
are used in the wiring of the
encoder.
1. Please connect the UVW
connector (color green) to
the heat sink of the servo
drive.
2. Please check if the encoder
cable separates from the
power supply or the high-
current circuit.
3. Please use shielding mesh.
4. If issue persists, please
send the drive back to the
distributors or contact Delta.
AL027:
The internal of the encoder is in error
Causes
Checking Method
Corrective Actions
The internal reset of
the encoder is in
error.
1. Check if the servo is properly
grounded.
2. Check if the encoder cable
separates from the power
supply or the high-current circuit
to avoid the interference.
3. Check if the shielding cables
are used in the wiring of the
encoder.
1. Please connect the UVW
connector (color green) to
the heat sink of the servo
drive.
2. Please check if the encoder
cable separates from the
power supply or the high-
current circuit.
3. Please use shielding mesh.
4. If issue persists, please
send the drive back to the
distributors or contact Delta.
AL028:
The internal of the encoder is in error
Causes
Checking Method
Corrective Actions
The encoder U, V, W
signals are in error.
1. Check if the servo is properly
grounded.
2. Check if the encoder cable
separates from the power
supply or the high-current circuit
to avoid the interference.
3. Check if the shielding cables
are used in the wiring of the
encoder.
1. Please connect the UVW
connector (color green) to
the heat sink of the servo
drive.
2. Please check if the encoder
cable separates from the
power supply or the high-
current circuit.
3. Please use shielding mesh.
4. If issue persists, please
send the drive back to the
distributors or contact Delta.
Содержание ASD-B2-1521-F
Страница 1: ......
Страница 20: ...ASDA B2 Chapter 1 Installation and Model Explanation Revision May 2018 1 7 1 4 Servo Drive Features...
Страница 81: ...Chapter 3 Wiring ASDA B2 3 42 Revision May 2018 This page is intentionally left blank...
Страница 103: ...Chapter 5 Trial Operation and Tuning ASDA B2 5 12 Revision May 2018 5 5 2 Inertia Estimation Flowchart with Mechanism...
Страница 124: ...ASDA B2 Chapter 6 Control Modes of Operation Revision May 2018 6 13...