ASDA-B2
Chapter 7 Parameters
Revision May, 2018
7-91
P4-12
SOF2 Analog Speed Input Offset Adjustment 2
Address: 0418H
0419H
Operation
Interface:
Panel / Software
Communication
Related Section: N/A
Default:
Factory setting
Control
Mode:
ALL
Unit: N/A
Range: 0 ~ 32767
Data Size: 16-bit
Format: Decimal
Settings: Manually adjust the hardware offset. The adjustment function
needs to be enabled by the setting of parameter P2-08. It is not
suggested to adjust the auxiliary adjustment. This parameter
cannot be reset.
P4-14
TOF2 Analog Torque Drift Adjustment 2
Address: 041CH
041DH
Operation
Interface:
Panel / Software
Communication
Related Section: N/A
Default:
Factory setting
Control
Mode:
ALL
Unit: N/A
Range: 0 ~ 32767
Data Size: 16-bit
Format: Decimal
Settings: Manually adjust the hardware offset. The adjustment function
needs to be enabled by the setting of parameter P2-08. It is not
suggested to adjust the auxiliary adjustment. This parameter
cannot be reset.