2.5 Specification of Circuit Breaker and Fuse
Caution: Please use the fuse and circuit breaker that is recognized by UL/CSA.
Servo Drive Model
Circuit Breaker
Fuse (Class T)
Operation Mode
General
General
ASD-B2-0121-B 5A
5A
ASD-B2-0221-B 5A
6A
ASD-B2-0421-B 10A
10A
ASD-B2-0721-B 10A
20A
ASD-B2-1021-B 15A
25A
ASD-B2-1521-B 20A
40A
ASD-B2-2023-B 30A
50A
ASD-B2-3023-B 30A
70A
If the servo drive equips with earth leakage circuit breaker for avoiding
electric leakage, please choose the current sensitivity which is over
200mA and can continue up to 0.1 seconds.