Chapter 7 Parameters
ASDA-B2
7-92
Revision May, 2018
P4-15
COF1
Current Detector (V1 phase) Offset
Adjustment
Address: 041EH
041FH
Operation
Interface:
Panel / Software
Communication
Related Section: N/A
Default:
Factory setting
Control
Mode:
ALL
Unit: N/A
Range: 0 ~ 32767
Data Size: 16-bit
Format: Decimal
Settings: Manually adjust the hardware offset. The adjustment function
needs to be enabled by the setting of parameter P2-08. It is not
suggested to adjust the auxiliary adjustment. This parameter
cannot be reset.
P4-16
COF2
Current Detector (V2 phase) Offset
Adjustment
Address: 0420H
0421H
Operation
Interface:
Panel / Software
Communication
Related Section: N/A
Default:
Factory setting
Control
Mode:
ALL
Unit: N/A
Range: 0 ~ 32767
Data Size: 16-bit
Format: Decimal
Settings: Manually adjust the hardware offset. The adjustment function
needs to be enabled by the setting of parameter P2-08. It is not
suggested to adjust the auxiliary adjustment. This parameter
cannot be reset.