ASDA-B2
Chapter 7 Parameters
Revision May, 2018
7-67
P2-37
DO6 DO6 Funcitonal Planning
Address: 024AH
024BH
Operation
Interface:
Panel/Software
Communication
Related Section:
Table 7.2
Default:
7
Control
Mode:
ALL
Unit: N/A
Range: 0 ~ 0x013F
(The last two codes are DO code)
Data Size: 16-bit
Format: Hexadecimal
Settings: Please refer to the description of P2-18
P2-38
Reserved
Address: 024CH
024DH
P2-39
Reserved
Address: 024EH
024FH
P2-40
Reserved
Address: 0250H
0251H
P2-41
Reserved
Address: 0252H
0253H
P2-42
Reserved
Address: 0254H
0255H
P2-43
NCF2 Resonance Suppression (Notch Filter) (2)
Address: 0256H
0257H
Operation
Interface:
Panel/Software
Communication
Related Section:
6.3.7
Default:
1000
Control
Mode:
ALL
Unit: Hz
Range: 50 ~ 2000
Data Size: 16-bit
Format: Decimal
Settings: The second setting value of resonance frequency. If P2-44 is set
to 0, this function is disabled. P2-23 and P2-24 are the first Notch
filter.