Chapter 7 Parameters
ASDA-B2
7-36
Revision May, 2018
P1-34
TACC Acceleration Constant of S-Curve
Address: 0144H
0145H
Operation
Interface:
Panel/Software
Communication
Related Section:
6.3.3
Default:
200
Control
Mode:
S
Unit: ms
Range: 1 ~ 20000
Data Size: 16-bit
Format: Decimal
Settings: The time that speed command accelerates from 0 to 3000 r/min.
P1-34, P1-35, and P1-36, the acceleration time of speed
command from zero to the rated speed, all can be set individually.
.
NOTE
When the source of speed command is analog, and P1-36 is set
to 0, it will disable S-curve function.
P1-35
TDEC Deceleration Constant of S-Curve
Address: 0146H
0147H
Operation
Interface:
Panel/Software
Communication
Related Section:
6.3.3
Default:
200
Control
Mode:
S
Unit: ms
Range: 1 ~ 20000
Data Size: 16-bit
Format: Decimal
Settings: The time that speed command decelerates from 3000 r/min to 0.
P1-34, P1-35, and P1-36, the deceleration time of speed
command from the rated speed to zero, all can be set individually.
NOTE
When the source of speed command is analog, and P1-36 is set
to 0, it will disable S-curve function.
Содержание ASD-B2-1521-F
Страница 1: ......
Страница 20: ...ASDA B2 Chapter 1 Installation and Model Explanation Revision May 2018 1 7 1 4 Servo Drive Features...
Страница 81: ...Chapter 3 Wiring ASDA B2 3 42 Revision May 2018 This page is intentionally left blank...
Страница 103: ...Chapter 5 Trial Operation and Tuning ASDA B2 5 12 Revision May 2018 5 5 2 Inertia Estimation Flowchart with Mechanism...
Страница 124: ...ASDA B2 Chapter 6 Control Modes of Operation Revision May 2018 6 13...