Chapter 7 Parameters
ASDA-B2
7-104
Revision May, 2018
Setting value: 0x11
DO
Name
Function Description of Digital Output (DO)
Trigger
Method
Control
Mode
WARN Warning output (Forward / reverse limit, communication
error, undervoltage)
Level
Triggered
All
Setting value: 0x19
DO
Name
Function Description of Digital Output (DO)
Trigger
Method
Control
Mode
SP_OK
Speed completed output: In speed mode, when the
deviation between the speed feedback and the
command is smaller than the setting value of P1-47,
then this DO is ON.
Level
Triggered S, Sz
NOTE
When P2-18 to P2-22 and P2-37 are set to 0, DI has no function.