P1-43
MBT2 Disable Delay Time of Brake
Address: 0156H
0157H
Operation
Interface:
Panel/Software
Communication
Related Section:
6.5.5
Default:
0
Control
Mode:
ALL
Unit: ms
Range: -1000 ~ +1000
Data Size: 16-bit
Format: Decimal
Settings: Set the delay time from servo OFF to switch off the signal of brake
(BRKR).
NOTE
(1) If the delay time of P1-43 has not finished yet and the motor
speed is slower than P1-38, the signal of brake (BRKR) will
be disabled.
(2) If the delay time of P1-43 is up and the motor speed is higher
than P1-38, the signal of brake (BRKR) will be disabled.
(3) When Servo OFF due to Alarm (except AL022) or
emergency, the setting of P1-43 is equivalent to 0 if P1-43 is
set to a negative value.
P1-44
▲
GR1 Gear Ratio (Numerator) (N1)
Address: 0158H
0159H
Operation
Interface:
Panel/Software
Communication
Related Section:
Section 6.2.3
Default:
16
Control
Mode:
PT
Unit: pulse
Range: 1 ~ (2
26
-1)
Data Size: 32-bit
Format: Decimal
Settings: Please refer to P2-60 ~ P2-62 for the setting of multiple gear ratio
(numerator).
NOTE
In PT mode, the setting value can be changed when Servo ON.
Содержание ASD-B2-1521-F
Страница 1: ......
Страница 20: ...ASDA B2 Chapter 1 Installation and Model Explanation Revision May 2018 1 7 1 4 Servo Drive Features...
Страница 81: ...Chapter 3 Wiring ASDA B2 3 42 Revision May 2018 This page is intentionally left blank...
Страница 103: ...Chapter 5 Trial Operation and Tuning ASDA B2 5 12 Revision May 2018 5 5 2 Inertia Estimation Flowchart with Mechanism...
Страница 124: ...ASDA B2 Chapter 6 Control Modes of Operation Revision May 2018 6 13...