ASDA-B2
Chapter 7 Parameters
Revision May, 2018
7-81
Settings:
0: 4800
1: 9600
2: 19200
3: 38400
4: 57600
5: 115200
P3-02
PTL Communication Protocol
Address: 0304H
0305H
Operation
Interface:
Panel / Software
Communication
Related Section:
8.2
Default:
0x0066
Control
Mode:
ALL
Unit: N/A
Range: 0x0000 ~ 0x0088
Data Size: 16-bit
Format: Hexadecimal
Settings: The definition of the setting value is as the followings:
0
Z
Y
X
COM Port
- -
RS-485
RS-232
Range
0
0
0 ~ 8
0 ~ 8
0: 7, N, 2 (MODBUS, ASCII)
1: 7, E, 1 (MODBUS, ASCII)
2: 7, O,1 (MODBUS, ASCII)
3: 8, N, 2 (MODBUS, ASCII)
4: 8, E, 1 (MODBUS, ASCII)
5: 8, O, 1 (MODBUS, ASCII)
6: 8, N, 2 (MODBUS, RTU)
7: 8, E, 1 (MODBUS, RTU)
8: 8, O, 1 (MODBUS, RTU)