Chapter 7 Parameters
ASDA-B2
7-26
Revision May, 2018
P1-02
▲
PSTL Speed and Torque Limit Setting
Address: 0104H
0105H
Operation
Interface:
Panel/Software
Communication
Related Section:
6.6
Default:
0
Control
Mode:
ALL
Unit: -
Range: 00 ~ 11
Data Size: 16-bit
Display
Format:
Hexadecimal
Settings:
Disable or Enable speed limit function
0: Disable speed limit function
1: Enable speed limit function (It is available in T mode only)
Others: Reserved
Block diagram of speed limit setting:
P1-09(1)
P1-10(2)
P1-11(3)
Vref
SPD0
SPD1
(0)
Speed Limit
Command
When desire to use speed limit function, users could use parameter setting
or DI triggering. That is to say, set P1-02 to 0x0001 or trigger DI will do.
Also, users could enable or disable the limit function via DI.SPDLM, which
is a more flexible way but would need to take one DI setting. Speed limit
can be enabled by P1-02 or DI.
DI.SPD0 and DI.SPD1 are for selecting the limiting source.
Disable or Enable torque limit function
0: Disable torque limit function
1: Enable torque limit function (It is available in position and speed mode)
Other: Reserved
Содержание ASD-B2-1521-F
Страница 1: ......
Страница 20: ...ASDA B2 Chapter 1 Installation and Model Explanation Revision May 2018 1 7 1 4 Servo Drive Features...
Страница 81: ...Chapter 3 Wiring ASDA B2 3 42 Revision May 2018 This page is intentionally left blank...
Страница 103: ...Chapter 5 Trial Operation and Tuning ASDA B2 5 12 Revision May 2018 5 5 2 Inertia Estimation Flowchart with Mechanism...
Страница 124: ...ASDA B2 Chapter 6 Control Modes of Operation Revision May 2018 6 13...