Chapter 7 Parameters
ASDA-B2
7-28
Revision May, 2018
P1-04
MON1 MON1 Analog Monitor Output Proportion
Address: 0108H
0109H
Operation
Interface:
Panel/Software
Communication
Related Section:
6.4.4
Default:
100
Control
Mode:
ALL
Unit: % (full scale)
Range: 0 ~ 100
Data Size: 16-bit
Format: Decimal
Settings: Please refer to the P1-03, for the setting of analog output
selection.
Example: P0-03 = 01 (MON1 is motor speed analog output,
MON2 is motor torque analog output)
MON1 output voltage= 8 ×
Motor speed
(unit: Volts)
(Max. motor speed ×
P1-04
)
100
MON2 output voltage= 8 ×
Motor toque
(unit: Volts)
(Max. motor torque ×
P1-05
)
100
P1-05
MON2 MON2 Analog Monitor Output Proportion
Address: 010AH
010BH
Operation
Interface:
Panel/Software
Communication
Related Section:
6.4.4
Default:
100
Control
Mode:
ALL
Unit: % (full scale)
Range: 0 ~ 100
Data Size: 16-bit
Format: Decimal
Settings: Please refer to the P1-03, for the setting of analog output
selection.
Example: P0-03 = 01 (MON1 is motor speed analog output,
MON2 is motor torque analog output)
MON1 output voltage= 8 ×
Motor speed
(unit: Volts)
(Max. motor speed ×
P1-04
)
100
MON2 output voltage= 8 ×
Motor torque
(unit: Volts)
(Max. motor torque ×
P1-05
)
100
Содержание ASD-B2-1521-F
Страница 1: ......
Страница 20: ...ASDA B2 Chapter 1 Installation and Model Explanation Revision May 2018 1 7 1 4 Servo Drive Features...
Страница 81: ...Chapter 3 Wiring ASDA B2 3 42 Revision May 2018 This page is intentionally left blank...
Страница 103: ...Chapter 5 Trial Operation and Tuning ASDA B2 5 12 Revision May 2018 5 5 2 Inertia Estimation Flowchart with Mechanism...
Страница 124: ...ASDA B2 Chapter 6 Control Modes of Operation Revision May 2018 6 13...