006: Overload
007: Over speed
008: Abnormal pulse command
009: Excessive deviation of position command
010: Reserved
011: Encoder error (The servo drive cannot connect to the
encoder because of disconnection or abnormal wiring)
012: Adjustment error
013: Emergency stop
014: Reverse limit error
015: Forward limit error
016: IGBT overheat
017: Abnormal EEPROM
018: Abnormal signal output
019: Serial communication error
020: Serial communication time out
021: Reserved
022: Main circuit power lack phase
023: Early warning for overload
024: Encoder initial magnetic field error
025: The internal of the encoder is in error
026: Unreliable internal data of the encoder
027: The internal of the encoder is in error
030: Motor crash error
031: Incorrect wiring of the motor power line, U, V, W, GND
099: DSP firmware upgrade
P0-02
STS Drive Status
Address: 0004H
0005H
Operation
Interface:
Panel/Software
Communication
Related Section:
Table 7.2
Default:
00
Control
Mode:
ALL
Unit: -
Range: -112, 0 ~ 111
Data Size: 16-bit
Format: Decimal
Settings: Input the monitoring variable to P0-02 in order to view changes
to the variable on the panel. For the list of monitoring variables,
please refer to Table 7.3 Monitoring Variables Descriptions.
Содержание ASD-B2-1521-F
Страница 1: ......
Страница 20: ...ASDA B2 Chapter 1 Installation and Model Explanation Revision May 2018 1 7 1 4 Servo Drive Features...
Страница 81: ...Chapter 3 Wiring ASDA B2 3 42 Revision May 2018 This page is intentionally left blank...
Страница 103: ...Chapter 5 Trial Operation and Tuning ASDA B2 5 12 Revision May 2018 5 5 2 Inertia Estimation Flowchart with Mechanism...
Страница 124: ...ASDA B2 Chapter 6 Control Modes of Operation Revision May 2018 6 13...