Chapter 6 Control Modes of Operation
ASDA-B2
6-44
Revision May, 2018
6.6.3 Analog Monitor
Users could observe the needed voltage signal via analog monitor. Two analog channels
are provided by the servo drive and locate in terminal 1 and 3 of CN5. The related
parameter settings are as the followings.
P0-03
MON Analog Monitor Output
Address: 0006H
0007H
Operation
Interface:
Panel/Software
Communication
Related Section:
Section 6.6.3
Default:
00
Control
Mode:
ALL
Unit: -
Range: 00 ~ 77
Data Size: 16-bit
Display
Format:
Hexadecimal
Settings:
MON1, MON2
Setting Value
Description
0
Motor speed (+/-8 Volts / Max. speed)
1
Motor torque (+/-8 Volts / Max. torque)
2
Pulse command frequency (+8 Volts / 4.5
Mpps)
3
Speed command (+/-8 Volts / Max. speed
command)
4
Torque command (+/-8 Volts / Max. torque
command)
5
VBUS voltage (+/-8 Volts / 450V)
6 Reserved
Содержание ASD-B2-1521-F
Страница 1: ......
Страница 20: ...ASDA B2 Chapter 1 Installation and Model Explanation Revision May 2018 1 7 1 4 Servo Drive Features...
Страница 81: ...Chapter 3 Wiring ASDA B2 3 42 Revision May 2018 This page is intentionally left blank...
Страница 103: ...Chapter 5 Trial Operation and Tuning ASDA B2 5 12 Revision May 2018 5 5 2 Inertia Estimation Flowchart with Mechanism...
Страница 124: ...ASDA B2 Chapter 6 Control Modes of Operation Revision May 2018 6 13...