Chapter 7 Parameters
ASDA-B2
7-78
Revision May, 2018
The timing charts of speed limit profile (with accel / decel
function) and torque command (TQP/TQN):
Bit1: Reserved
Bit2: Cancel latch function of low-voltage error
0: Latch function of low-voltage error: the error will not be
cleared automatically.
1: Cancel latch function of low-voltage error: the error will be
cleared automatically.
Bit7: Cancel the display of motor temperature warning
0: Display motor temperature wanring
1: Cancel the display of motor temperature warning
Bit3 ~ Bit6: Reserved
Bit9:
0: When AL.003 occurs, switch on DO.WARN. (DO function
0x11)
1: When AL.003 occurs, switch on (DO function 0x07)
Bit15: Selection of dncoder pulse output
0: 0x0000. The setting value of P1-46 represents the
single-phase pulse number when motor runs a cycle.
If P1-46 is set to 2,500 pulse, then the host controller will
receive 10, 000 pulse (the quadruple of the single-phase pulse
number) when motor runs a cycle.
Motor runs a cycle
Para. setting: P1-46=4, 2-66=0x0000
OA