P2-23
NCF1 Resonance Suppression (Notch Filter) (1)
Address: 022EH
022FH
Operation
Interface:
Panel/Software
Communication
Related Section:
6.2.5
Default:
1000
Control
Mode:
ALL
Unit: Hz
Range: 50 ~ 2000
Data Size: 16-bit
Format: Decimal
Settings: The first setting value of resonance frequency. If P2-24 is set to 0,
this function is disabled. P2-43 and P2-44 are the second Notch
filter.
P2-24
DPH1
Resonance Suppression (Notch filter)
Attenuation Rate (1)
Address: 0230H
0231H
Operation
Interface:
Panel/Software
Communication
Related Section:
6.3.7
Default:
0
Control
Mode:
ALL
Unit: dB
Range: 0 ~ 32 (0: Disabled)
Data Size: 16-bit
Format: Decimal
Settings: The first resonance suppression (notch filter) attenuation rate.
When this parameter is set to 0, the function of Notch filter is
disabled.
P2-25
NLP
Low-pass Filter of Resonance
Suppression
Address: 0232H
0233H
Operation
Interface:
Panel/Software
Communication
Related Section:
6.3.7
Default: 0.2 (1kW and below
models) or 0.5 (other
models)
2 (1kW and below
models) or 5 (other
models)
Control
Mode:
ALL
Unit:
1ms
0.1ms
Range: 0.0 ~ 100.0
0 ~ 1000
Data
Size:
16-bit
Format:
One-digit
Decimal
Example: 1.5 = 1.5 msec
15 = 1.5 msec
Settings: Set the low-pass filter of resonance suppression. When the value
is set to 0, the function of low-pass filter is disabled.
Содержание ASD-B2-1521-F
Страница 1: ......
Страница 20: ...ASDA B2 Chapter 1 Installation and Model Explanation Revision May 2018 1 7 1 4 Servo Drive Features...
Страница 81: ...Chapter 3 Wiring ASDA B2 3 42 Revision May 2018 This page is intentionally left blank...
Страница 103: ...Chapter 5 Trial Operation and Tuning ASDA B2 5 12 Revision May 2018 5 5 2 Inertia Estimation Flowchart with Mechanism...
Страница 124: ...ASDA B2 Chapter 6 Control Modes of Operation Revision May 2018 6 13...