Chapter 7 Parameters
ASDA-B2
7-6
Revision May, 2018
Speed Control Parameter
Parameter Abbr.
Function
Default Unit
Control Mode Related
Section
PT S
T
P1-01
CTL
Input Setting of Control Mode
and Control Command
0
pulse
r/min
N-M
O O O 6.1
P1-02
▲
PSTL
Speed and Torque Limit
Setting
0 N/A
O
O
O
6.6
P1-46
▲
GR3
Output Pulse Counts Per One
Motor Revolution
1 pulse
O
O
O -
P1-55
MSPD Maximum Speed Limit
rated
r/min O O O
-
P1-09 ~
P1-11
SP1 ~ 3
Internal Speed Command 1 ~
3
1000 ~
3000
0.1
r/min
O O 6.3.1
P1-12 ~
P1-14
TQ1 ~ 3 Internal Torque Limit 1 ~ 3
100
%
O O O
6.6.2
P1-40
▲
VCM
Maximum Speed of Analog
Speed Command
rated r/min O O 6.3.4
P1-41
▲
TCM
Maximum Output of Analog
Torque Speed
100 % O
O
O -
P1-76 AMSPD
Maximum Rotation Setting of
Encoder Setting (OA, OB)
5500 r/min O O O -
(
★
)
Read-only register,
e.g.
parameter P0-00, P0-10 and P4-00, etc.
(
▲
)
Setting is invalid when Servo On, e.g. parameter P1-00, P1-46 and P2-33, etc.
(
)
Not effective until re-power on or off the servo drive, e.g. parameter P1-01 and
P3-00.
(
)
Volatile parameters, e.g. parameter P2-30 and P3-06
.
Содержание ASD-B2-1521-F
Страница 1: ......
Страница 20: ...ASDA B2 Chapter 1 Installation and Model Explanation Revision May 2018 1 7 1 4 Servo Drive Features...
Страница 81: ...Chapter 3 Wiring ASDA B2 3 42 Revision May 2018 This page is intentionally left blank...
Страница 103: ...Chapter 5 Trial Operation and Tuning ASDA B2 5 12 Revision May 2018 5 5 2 Inertia Estimation Flowchart with Mechanism...
Страница 124: ...ASDA B2 Chapter 6 Control Modes of Operation Revision May 2018 6 13...